Robot-assisted pelvic surgery: the robot-specific cognitive risk remains uncertain

Cognitive disorders and episodes of delirium are reported after robot-assisted pelvic surgery. But their frequency in these studies does not demonstrate that the robot or surgical position is responsible. A systematic review of 25 studies mainly highlights the limitations of the available data. Only its PubMed abstract was consulted.

Illustration of a robot-assisted surgical system in an operating room.
Gadgets & TechEditorial illustration, not study data.

Findings from selected populations

The review includes 26 publications corresponding to 25 studies in adults undergoing robot-assisted pelvic surgery. Eligible studies had to report objective cognitive tests or episodes of delirium. The literature search covers publications available through August 4, 2026.

Across five prospective cohorts totaling 356 participants, the pooled proportion of cognitive decline was 29.0%, with a 95% confidence interval ranging from 20.2 to 39.8%. This figure describes the outcomes as defined by each study in the selected groups. It is not a probability applicable to everyone undergoing this surgery.

For delirium, three cohorts totaling 245 participants yielded a pooled descriptive estimate of 10.3%. Its confidence interval was wide, ranging from 2.2 to 37.0%. The proportions observed in the three cohorts were 9.8%, 5.0% and 16.9%, respectively, calling for caution when interpreting a single figure.

A disorder after surgery does not prove an effect of the robot

The comparison involving the same procedure, prostatectomy, reports an unadjusted relative risk of early cognitive decline of 1.06, with a confidence interval of 0.73 to 1.55. It therefore does not clearly show a difference in risk. Nor does it demonstrate that the techniques are equivalent, since the interval remains compatible with both a decrease and an increase in risk.

The authors rate the comparative evidence as low or very low certainty. Differences in the definitions of the disorders, monitoring and participant selection limit interpretation. The abstract also does not allow a uniform follow-up duration to be specified or any conclusion about whether the disorders persist.

No established positioning threshold

Findings concerning time spent in the Trendelenburg position are inconsistent. This synthesis establishes neither a risk attributable to this position, nor a safe duration of exposure, nor any benefit from breaks in a horizontal position.

What this review changes is mainly how the figures should be read: cognitive events are documented after these procedures, but whether they can be attributed to the robot or positioning remains uncertain. The authors call for standardized prospective measurements to make studies more comparable.

Limitations to keep in mind

Only the PubMed abstract was consulted, not the full text. The cohorts are selected, definitions and monitoring vary, and the comparative evidence is of low or very low certainty. Funding and conflicts of interest were not checked.

What we can take away

This review documents cognitive disorders after robot-assisted pelvic surgery, without demonstrating any additional risk specific to the robot or justifying a specific change in positioning.

Sources and provenance

Partager cet article

X f in

An error or a source to report? Contact the editorial team.